MPC2000 Reference Manual [JAPANESE] [ENGLISH]
yCommandz   yUSBz
yUSEz
RST_USB

RST_USB : TIME 2000
yFORMATz yFUNCTIONz
RST_USB

yEXPLANATIONz





ON_ERROR *ERROR_PROC
ON_USB
TIME 2000
FILE$=HEX$(DATE(0))+".CSV"
USB_DEL FILE$ /* Delete a file
DO
FORMAT "00:00:00"
WRITE_STR$=HEX$(TIME(0))+"\n"
USB_WRITE WRITE_STR$ /* Write to the USB Memory
TIME 5000
LOOP

*ERROR_PROC /* Error process
err_code=err_>>24 /* Get an error code
err_step=err_&&H00FFFFFF /* Get an error step number
PR "ERROR CODE" err_code "ERROR STEP" err_step
WAIT SW(192)==1 /* Restart
TIME 1000
RST_USB /* Reset the USB memory
TIME 2000
RESUME