MPC2000 Reference Manual [JAPANESE] [ENGLISH]
yCommandz   yPulseGenz
yUSEz
SYNC

SYNC X_A &H00004001 0
SYNC Z_A 0 4
yFORMATz yFUNCTIONz
SYNC axs WR6 WR7

Setting MCX-314 register value
yEXPLANATIONz





ACCEL Z_A|OUTSL 1000000 10000 1000000
ACCEL X_A|OUTSL 3000
INSET X_A CMP_CNT|PHASE2

SYNC X_A &H00004001 0
SYNC Z_A 0 4
CLRPOS Z_A
RANGE Z_A 50 0
RANGE X_A 100 0
'
WAIT CMP_C(Z_A)!=0
STOP Z_A STP_I
WAIT RR(Z_A)==0
[LASTMODIFY]2012-01-19 18:42:33 [CREATEDATE]2011-12-20 15:57:50